安裝防火閥熔斷片時(shí)的注意事項(xiàng)

來(lái)源:http://www.glsytz.com/     發(fā)布時(shí)間:2017-07-24  

  一、山東通風(fēng)管道加工排煙防火閥氣密性強(qiáng)主要體現(xiàn)在以下四個(gè)方面:

  First, smoke smoke damper strong air tightness, mainly reflected in the following four aspects:

  1、執(zhí)行機(jī)構(gòu)驅(qū)動(dòng)靈活。反饋、聯(lián)鎖信號(hào)準(zhǔn)確。

  1, actuators flexible. The feedback and interlocking signals are accurate.

  2、漏風(fēng)量低,氣密性能好。

  2 、 the air leakage is low, and the air tightness is good.

  3、電動(dòng)開啟消耗電流小。

  3 、 electric opening consumes little current.

  4、防腐性能強(qiáng),使用壽命長(zhǎng)。

  4, corrosion resistance, long service life.
濟(jì)南通風(fēng)管道工程

  二、在裝修排煙防火閥時(shí)可以參照這些要點(diǎn)進(jìn)行檢查,可以減少后期的損害,主要有以下五點(diǎn):

  Two, in the decoration smoke smoke fire valve can refer to these points for inspection, can reduce the damage later, mainly has the following five points:

  1、排煙防火閥的熔斷片應(yīng)裝在朝向火災(zāi)危險(xiǎn)性較大的一側(cè)。

  1. The fuse shall be installed on the side of the fire danger.

  2、排煙防火閥可與通風(fēng)機(jī)、排煙風(fēng)機(jī)聯(lián)鎖,閥門的操作機(jī)構(gòu)一側(cè)應(yīng)有不小于200mm的凈空間以利檢修。

  2, smoke fire dampers can be ventilation, smoke exhaust fan interlock, the valve side of the operating mechanism should be less than 200mm of the net space, in order to facilitate maintenance.

  3、排煙防火閥應(yīng)單獨(dú)設(shè)支吊架,以防止發(fā)生火災(zāi)時(shí)管道變形影響其性能。

  3 smoke exhaust fire valve shall be provided with separate hangers to prevent pipe deformation during fire and affect its performance.

  4、安裝排煙防火閥閥門前必須檢查閥門的操作機(jī)構(gòu)是否完好,動(dòng)作是否靈活有效。

  4, the installation of smoke fire valve, valve must check whether the operation of the valve is intact, the action is flexible and effective.

  5、排煙防火閥應(yīng)安裝在緊靠墻或樓板的風(fēng)管管段中,防火分區(qū)隔墻兩側(cè)的防火閥距墻表面不應(yīng)大于200mm,防火閥兩側(cè)各2.0m范圍內(nèi)的管道及其絕熱材料應(yīng)采用不燃材料。

  5, smoke fire pipe valve should be installed in the wall or floor close to the wind in the fire valve fire partition walls on both sides of the distance from the wall surface should be no more than 200mm, the pipeline fire valve on both sides of the range of 2.0m and the adiabatic material should use non combustible materials.

  本文由山東通風(fēng)管道加工為您提供,我們的網(wǎng)站是:http://www.glsytz.com/我們將以全心全意的熱情為您提供更的服務(wù),歡迎您的訪問!

  This article by the Shandong ventilation pipe processing provides for you, our website is: http://www.glsytz.com/, we will wholeheartedly wholeheartedly provide you with better service, you are welcome to visit!

上一篇:通風(fēng)管道風(fēng)量調(diào)節(jié)閥的選用參數(shù)
下一篇:鋁箔復(fù)合排煙罩的清洗事項(xiàng)