1、濟(jì)南風(fēng)管加工工程量計(jì)算,不分材質(zhì)均以施工圖示風(fēng)管線長(zhǎng)度為準(zhǔn),按風(fēng)管不同斷面形狀(圓、方、矩)的展開面積計(jì)算,以計(jì)量。
1. Jinan air duct processing quantity calculation, regardless of material, is based on the length of the air duct center line in the construction drawing, and is calculated according to the unfolded area of different cross-section shapes (circle, square and moment), measured in square meters.
①、圓形風(fēng)管展開面積,不扣除檢查孔、測(cè)定孔、送風(fēng)口、吸風(fēng)口等所占面積,咬口重疊所占面積,咬口重疊部分也不增加。
① The developed area of circular air duct does not deduct the area occupied by inspection hole, measuring hole, air supply outlet and air suction outlet, and the overlapping area of biting does not increase.
②風(fēng)管加工長(zhǎng)度計(jì)算,一律以施工圖所示線長(zhǎng)度為準(zhǔn),包括彎頭、三通、變徑管、天圓地方管件長(zhǎng)度。支管長(zhǎng)度以支管線與主管線交接點(diǎn)為分界點(diǎn)。風(fēng)管長(zhǎng)度不包括部件所占長(zhǎng)度,其部件長(zhǎng)度值見下表:序號(hào) 部件名稱 部件長(zhǎng)度 序號(hào) 部件名稱 部件長(zhǎng)度 1 蝶閥 150 4 圓形風(fēng)管防火閥 D+240 2 止回閥 300 5 矩形風(fēng)管防火閥 B+240 3 密閉式對(duì)開多頁(yè)調(diào)節(jié) 閥 210 注:D為風(fēng)管外徑,B為方風(fēng)管外邊高。
② The processing length of air duct shall be calculated according to the center line length shown in the construction drawing, including the length of elbow, tee, reducing pipe and pipe fitting at Tianyuan place. The length of branch pipe is divided by the junction point between the center line of branch pipe and the center line of main pipe. The length of the air duct does not include the length of the components. The length values of the parts are shown in the following table: serial number component name part length serial number part length 1 butterfly valve 150 4 circular air duct fire damper D + 240 2 check valve 300 5 rectangular air duct fire damper B + 240 3 closed type split multi leaf regulating valve 210 note: D is the outer diameter of the air duct, B is the outer edge height of the square air duct.
③、風(fēng)管加工與安裝定額包括:彎頭、三通、變徑管、天圓地方等管件及發(fā)蘭、加固框和吊架、托架、支架的制作與安裝。未計(jì)價(jià)材料計(jì)算了鈑材料,而發(fā)蘭和支架、吊架、托架按定額規(guī)定計(jì)算其價(jià)值后,還要計(jì)算其材料數(shù)量,并按規(guī)格、品種列入材料匯總表中。風(fēng)管制作與安裝定額不包括:過跨風(fēng)管的落地支架制作安裝。落地支架以“千克”計(jì)量,使用第九篇《通風(fēng)空調(diào)工程》定額第七章設(shè)備支架子目。
③ Air duct processing and installation norms include: elbow, tee, reducing pipe, Tianyuan place and other pipe fittings and flange, reinforcement frame and hanger, bracket, bracket and installation. The sheet material is calculated for the unpriced materials, and after the value of the flange, bracket, hanger and bracket is calculated according to the quota, the material quantity shall be calculated and listed in the material summary table according to the specifications and varieties. The production and installation quota of air duct does not include: the manufacture and installation of floor support for crossing air duct. The floor support is measured in kilogram, and the equipment support subitem in Chapter 7 of the quota of Chapter IX ventilation and air conditioning engineering is used.
④、凈化通風(fēng)管道及部件制作與安裝,工程量計(jì)算方法與一般通風(fēng)管道相同,用相應(yīng)定額。但是零部件安裝要計(jì)算凈化費(fèi),按相應(yīng)部件子目安裝基價(jià)的35%作為凈化費(fèi),其中人工費(fèi)占40%。對(duì)凈化管道與建筑物縫隙之間所作的精華密封處理,按實(shí)計(jì)算費(fèi)用。
④ For the fabrication and installation of purification ventilation pipeline and components, the calculation method of engineering quantity is the same as that of general ventilation pipeline, and the corresponding quota is used. However, the purification cost should be calculated for the installation of parts, and 35% of the basic installation price of the corresponding component subitems is taken as the purification cost, of which the labor cost accounts for 40%. The essence seal treatment between the purge pipe and the building gap is processed according to the actual cost.